STRATIGRAPHY 1 - Winkler Chimica

ROOT-PROOF BITUMINOUS WATERPROOFING

Underground structure, externally waterproofed with heat-applied bituminous membrane, resistant to root penetration

1 LEAN CONCRETE LAYER FOR FOUNDATION

2 PRIMER

Application by roller, brush, or spray of bituminous primer ECOIMPRIMER, total consumption 150–200 g/m².

3 HORIZONTAL WATERPROOFING

Executed with hot-applied elastoplastomeric bituminous membrane (BPP) COVERBOND ANTIRADICE, with low-temperature flexibility down to –10 °C. The membrane is reinforced with non-woven polyester fabric stabilized with glass fibers, rot-proof, and suitable for applications requiring resistance to root penetration.

4 FOUNDATION ELEVATION STRUCTURE: CONSTRUCTED IN REINFORCED CONCRETE

5 VERTICAL STRUCTURE WATERPROOFING

Executed with hot-applied elastoplastomeric bituminous membrane (BPP) COVERBOND ANTIRADICE, with low-temperature flexibility down to –10 °C. The membrane is reinforced with non-woven polyester fabric stabilized with glass fibers, rot-proof, and suitable for applications requiring resistance to root penetration.

6 PROTECTIVE ELEMENT

7 BACKFILLING