STRATIGRAPHY 1 - Winkler Chimica

WATERPROOFING WITH HEAT-APPLIED BITUMINOUS MEMBRANE AND REFLECTIVE PROTECTION

Warm roof with thermalinsulation panel, waterproofed with a double layer of smooth bituminous membrane, applied hot, completed with a protective, reflective liquid coating, resistant to water stagnation and suitable for the application of new membranes

1 SUPPORT / LOAD-BEARING ELEMENT

It must have a minimum slope of 1%. Alternatively, a sloping screed can be created using WINPLAN 370 or WINPLAN PRO. For bonded screeds with a thickness between 1 and 3 cm, it is recommended to use WINGRIP® NEXT as a fresh-on-fresh adhesion promoter.

2 PRIMER

Roller, brush or spray of the bituminous primer ECOIMPRIMER, with a total consumption 150–200 g/m².

3 VAPOR BARRIER

Hot application of the COVERBLOCK 4 mm bitumen-polymer membrane, which functions as a vapor barrier and is reinforced with a glass–fiber mat coupled with rot-proof aluminum foil.

4 ADHESIVE FOR INSULATION BOARDS

Roller or brush application of the water-based bituminous adhesive WINGLUE or WINGLUE FAST,
with a Consumption of 0.8 kg/m².

5 THERMAL INSULATION ELEMENT

suitable for torch application of bituminous membranes.

6 WATERPROOFING (FIRST LAYER)

First layer of EXPERTA 300 elastoplastomeric (BPP) bituminous membrane applied by torch, featuring cold flexibility of –15 °C and reinforced with a rot-proof continuous-filament polyester non-woven fabric stabilized with glass.

7 WATERPROOFING (SECOND LAYER)

Second layer of EXPERTA 400 elastoplastomeric (BPP) bituminous membrane applied by torch, featuring cold flexibility of –20 °C and reinforced with a rot-proof continuous-filament polyester non-woven fabric stabilized with glass.

8 FIXATIVE OIL PRIMER

Roller, brush, or spray application 2000 FAST PRIMER fixativeoil primer. At 20 °C, it can be overcoated in just 3 hours. Consumption: 250 g/m².

9 REFLECTIVE PROTECTIVE COATING

Roller, brush, or spray application of 2000 FAST REFLEX, a high-reflectance protective coating resistant to standing water, UV rays, and  atmospheric agents. With a reflectance index of SRI 108, it reduces roof temperatures, ensuring long-lasting material durability and improved building comfort. Consumption: 1 kg/m² in two coats.

10 COPING FLASHING