COATING SYSTEM FOR ASBESTOS-CEMENT ROOFS
1 EXISTING ASBESTOS-CEMENT ROOF
2 PRIMER
Application by roller, brush, or spray of BASE I, an elastomeric primer in water-based emulsion used as an adhesion promoter for the Wincoat asbestos protection system.
To be applied in two coats, with a 12-hour interval between coats, for a total consumption of 300 g/m².
3 PROTECTIVE, ENCAPSULATING LAYER
Protective, encapsulating layer: Application of VISTA INCAPSULANTE, a pigmented protective coating based on elastomeric polymers in aqueous dispersion, used within the Wincoat system for the encapsulation of asbestos-cement sheets and structures.
The product is ready to use and can be applied by roller, brush, or airless spray in two coats, with a total consumption of approximately 500 g/m², achieving a thickness of about 350 microns.
4 PROTECTIVE, FINISHING LAYER
Application of VISTA FINITURA, a pigmented protective coating based on elastomeric polymers in aqueous dispersion, used as the finishing layer within the Wincoat system for asbestos-cement sheets and structures.
A different color from the encapsulating layer is used to allow visual monitoring of layer wear.
Applied by roller, brush, or airless spray in two coats, with a total consumption of 500 g/m².