Waterproofing with drive-over liquid membrane
Application of waterproofing with liquid membrane suitable for driveway traffic
1 STRUCTURAL ELEMENT / CONCRETE SUBFLOOR WITH JOINTS
2 CORNER REINFORCEMENT
Apply self-adhesive butyl tape BC SEAL BAND in corners. Used together with BC SEAL PAD for sealing drains, outlets, and penetrations
3 WALKABLE ANTI-SLIP HORIZONTAL WATERPROOFING, FIRST LAYER
Application of ONE FLOORING system with roller, brush, or spray. Suitable for high traffic, puncture-resistant, and applicable on damp surfaces and extreme temperatures (0–45 °C). Applied in three layers; first layer consumption 0.4 kg/m²
4 WALKABLE ANTI-SLIP HORIZONTAL WATERPROOFING, SECOND LAYER
Creation of the flooring and waterproofing by roller, brush or spray application of the ONE FLOORING system, consumption 1.2 kg/m2, and third coat 0.3 kg/m2
5 Walkable anti-slip horizontal waterproofing, third layer
Creation of the flooring and waterproofing by roller, brush or spray application of the ONE FLOORING system, consumption 1.2 kg/m2, and third coat 0.3 kg/m2
6 VERTICAL UPSTAND WATERPROOFING
Application of ONE VERTICAL system with roller, brush, or spray. Thixotropic waterproofing for vertical upstands and details, puncture-resistant, applicable on damp surfaces and extreme temperatures (0–45 °C). Applied in a single layer, consumption 0.35 kg/m²
7 JOINT SEALING
After creating new joints or restoring existing ones, use a joint sealing system composed of WINJOINT FOAM compressible backer rod and WINJOINT SEAL polyurethane sealant