Restoration and waterproofing of front panels and concrete details with waterproof smoothing
Intervention cycle for the restoration of damaged front panels and concrete details, with subsequent covering with a waterproof cement membrane
1 ARCHITECTURAL DETAIL / FASCIA
2 REINFORCEMENT PASSIVATION
Apply WAR M, a single-component cement-based product with corrosion inhibitors for the protection of reinforcement bars, using a brush on previously cleaned metal. Consumption is 200 g/ml for bars with 8–10 mm diameter
3 COVER RESTORATION
For horizontal and flat areas, use WR02 WINREPAIR, a flowable premixed cementitious mortar, class R4. For vertical areas, use WR07 FIBROWIN, a single-component thixotropic fiber-reinforced mortar, class R4
4 CORNER REINFORCEMENT
Apply BC SEAL BAND self-adhesive butyl strip in the corners. Together with BC SEAL PAD, it is used for covering drains, outlets, and penetrations
5 WALL WATERPROOFING, FIRST COAT
Apply WINTAPLAST, a two-component, elastic, colored, UV-resistant, and hydrostatically resistant mortar. Its high elasticity is maintained over time, making it suitable for large surfaces. It also has high abrasion resistance and can be left exposed. Applied with a spatula, total consumption 2 kg/m²
6 WALL WATERPROOFING, SECOND COAT
Apply WINTAPLAST, a two-component, elastic, colored, UV-resistant, and hydrostatically resistant mortar. Applied with a spatula, total consumption 2 kg/m²